Cloned SEACAS for EXODUS library with extra build files for internal package management.
You can not select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
 
 
 
 
 
 

74 lines
2.3 KiB

C Copyright(C) 1999-2020 National Technology & Engineering Solutions
C of Sandia, LLC (NTESS). Under the terms of Contract DE-NA0003525 with
C NTESS, the U.S. Government retains certain rights in this software.
C
C See packages/seacas/LICENSE for details
C=======================================================================
SUBROUTINE SHPTIM (WHONLY, NPTIMS, IPTIMS, TIMES, WHOTIM)
C=======================================================================
C --*** SHPTIM *** (TIMSEL) Display time request
C -- Written by Amy Gilkey - revised 02/01/88
C --
C --SHPTIM displays the selected times.
C --
C --Parameters:
C -- WHONLY - IN - true iff only whole times may be selected
C -- NPTIMS - IN - the number of selected times
C -- IPTIMS - IN - the selected time steps
C -- TIMES - IN - the database times
C -- WHOTIM - IN - true iff TIMES(i) is whole (versus history) time step
C --Routines Called:
C -- LENSTR - (STRLIB) Find string length
C -- NUMSTR - (STRLIB) Convert numbers to engineering notation
C -- SQZSTR - (STRLIB) Delete extra blanks from string
LOGICAL WHONLY
INTEGER NPTIMS
INTEGER IPTIMS(*)
REAL TIMES(*)
LOGICAL WHOTIM(*)
CHARACTER*5 ISTRA
CHARACTER*20 RSTR(3)
REAL RNUM(3)
WRITE (*, *)
IF (.NOT. WHONLY) THEN
NPTIMW = NWHSEL (NPTIMS, IPTIMS, WHOTIM)
ELSE
NPTIMW = NPTIMS
END IF
NPTIMH = NPTIMS - NPTIMW
CALL INTSTR (1, 0, NPTIMS, ISTRA, LSTRA)
WRITE (*, 10010)
& ISTRA(:LSTRA), ' selected time steps'
IF (NPTIMS .GT. 0) THEN
MXSTEP = 0
DO 100 I = 1, NPTIMS
MXSTEP = MAX (MXSTEP, IPTIMS(I))
100 CONTINUE
CALL INTSTR (1, 0, MXSTEP, ISTRA, LSTRA)
RNUM(2) = TIMES(IPTIMS(1))
IF ((RNUM(2) .EQ. 0.0) .AND. (NPTIMS .GT. 1))
& RNUM(2) = TIMES(IPTIMS(2))
RNUM(3) = TIMES(IPTIMS(NPTIMS))
DO 110 I = 1, NPTIMS
CALL INTSTR (1, LSTRA, IPTIMS(I), ISTRA, L)
RNUM(1) = TIMES(IPTIMS(I))
CALL NUMSTR (3, 4, RNUM, RSTR, LSTR)
WRITE (*, 10000, IOSTAT=IDUM) I,
& ISTRA(:L), RSTR(1)(:LSTR)
110 CONTINUE
END IF
RETURN
10000 FORMAT (1X, I5, ')', 3X, '(step ', A, ')', 3X, A)
10010 FORMAT (1X, 5A)
END