LOGICAL FUNCTION PLTG2D(XG,YG,XD,YD)
DIMENSION UMAP(14)
REAL TYPE(1)
PLTG2D = .FALSE.
CALL PLTGTG(27,UMAP)
CALL PLTGTG(9,TYPE)
IF (TYPE(1).EQ.1.) THEN
XD = XG*UMAP(1) + YG*UMAP(3) + UMAP(5)
YD = XG*UMAP(2) + YG*UMAP(4) + UMAP(6)
ELSE IF (TYPE(1).EQ.2.) THEN
IF (XG.LE.0.) THEN
CALL PLTFLU
CALL SIORPT('PLTG2D',
* 'Cannot convert a negative number on log x axis.'
* ,2)
RETURN
END IF
XD = LOG10(XG)*UMAP(1) + YG*UMAP(3) + UMAP(5)
YD = LOG10(XG)*UMAP(2) + YG*UMAP(4) + UMAP(6)
ELSE IF (TYPE(1).EQ.3.) THEN
IF (YG.LE.0.) THEN
CALL PLTFLU
CALL SIORPT('PLTG2D',
* 'Cannot convert a negative number on log y axis.'
* ,2)
RETURN
END IF
XD = XG*UMAP(1) + LOG10(YG)*UMAP(3) + UMAP(5)
YD = XG*UMAP(2) + LOG10(YG)*UMAP(4) + UMAP(6)
ELSE IF (TYPE(1).EQ.4.) THEN
IF (XG.LE.0.) THEN
CALL PLTFLU
CALL SIORPT('PLTG2D',
* 'Cannot convert a negative number on log x axis.'
* ,2)
RETURN
END IF
IF (YG.LE.0.) THEN
CALL PLTFLU
CALL SIORPT('PLTG2D',
* 'Cannot convert a negative number on log y axis.'
* ,2)
RETURN
END IF
XD = LOG10(XG)*UMAP(1) + LOG10(YG)*UMAP(3) + UMAP(5)
YD = LOG10(XG)*UMAP(2) + LOG10(YG)*UMAP(4) + UMAP(6)
END IF
PLTG2D = .TRUE.
RETURN