Cloned SEACAS for EXODUS library with extra build files for internal package management.
You can not select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
 
 
 
 
 
 

692 lines
19 KiB

<!-------- @HEADER
!
! !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!
! Zoltan Toolkit for Load-balancing, Partitioning, Ordering and Coloring
! Copyright 2012 Sandia Corporation
!
! Under the terms of Contract DE-AC04-94AL85000 with Sandia Corporation,
! the U.S. Government retains certain rights in this software.
!
! Redistribution and use in source and binary forms, with or without
! modification, are permitted provided that the following conditions are
! met:
!
! 1. Redistributions of source code must retain the above copyright
! notice, this list of conditions and the following disclaimer.
!
! 2. Redistributions in binary form must reproduce the above copyright
! notice, this list of conditions and the following disclaimer in the
! documentation and/or other materials provided with the distribution.
!
! 3. Neither the name of the Corporation nor the names of the
! contributors may be used to endorse or promote products derived from
! this software without specific prior written permission.
!
! THIS SOFTWARE IS PROVIDED BY SANDIA CORPORATION "AS IS" AND ANY
! EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
! IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
! PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL SANDIA CORPORATION OR THE
! CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL,
! EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO,
! PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR
! PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF
! LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING
! NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS
! SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
!
! Questions? Contact Karen Devine kddevin@sandia.gov
! Erik Boman egboman@sandia.gov
!
! !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!
! @HEADER
------->
<!doctype html public "-//w3c//dtd html 4.0 transitional//en">
<html>
<head>
<meta http-equiv="Content-Type" content="text/html; charset=iso-8859-1">
<meta name="GENERATOR" content="Mozilla/4.7 [en] (X11; U; SunOS 5.6 sun4m) [Netscape]">
<meta name="sandia.approval_type" content="formal">
<meta name="sandia.approved" content="SAND2007-4748W">
<meta name="author" content="Zoltan PI">
<title>Zoltan User's Guide: Backward Compatilibity</title>
</head>
<body bgcolor="#FFFFFF">
<div align=right><b><i><a href="ug.html">Zoltan User's Guide</a>&nbsp; |&nbsp; <a href="ug_refs.html">Next</a>&nbsp; |&nbsp; <a href="ug_release.html">Previous</a></i></b></div>
<!---------------------------------------------------------------------------->
<h2>
Backward Compatibility with Previous Versions of Zoltan
</h2>
As new features have been added to Zoltan, backward compatibility with previous
versions of Zoltan has been maintained. Thus, users of previous versions of
Zoltan can upgrade to a new version <b> without changing their application
source code</b>.
Modifications to application source code are needed <b>only</b> if the
applications use new Zoltan functionality.
<p>
Enhancements to the Zoltan interface are described below.
<blockquote>
<a href="#Backward v3.8">Versions 3.8 and higher</a>
<br><a href="#Backward v3.6">Versions 3.6 and higher</a>
<br><a href="#Backward v3.2">Versions 3.2 and higher</a>
<br><a href="#Backward v3.1">Versions 3.1 and higher</a>
<br><a href="#Backward v3.0">Versions 3.0 and higher</a>
<br><a href="#Backward v1.5">Versions 1.5 and higher</a>
<br><a href="#Backward v1.3">Versions 1.3 and higher</a>
</blockquote>
<!---------------------------------------------------------------------------->
<h2><a name="Backward v3.8"></a>
<hr>Backward Compatibility: Versions 3.8 and higher
</h2>
<ul>
<li>
Zoltan is now released under Trilinos' BSD license.
</li>
<li>
All deprecated features in <a href="#Backward v3.6">version 3.6</a>
are now removed from Zoltan. See notes <a href="#Backward v3.6">below</a>.
</li>
</ul>
<!---------------------------------------------------------------------------->
<h2><a name="Backward v3.6"></a>
<hr>Backward Compatibility: Versions 3.6 and higher
</h2>
<ul>
<li>
Interfaces to Zoltan defined in lbi_const.h are now deprecated. Users should
upgrade to interfaces in zoltan.h. File lbi_const.h should not be included
in user files; rather, file zoltan.h should be included. File lbi_const.h will
not be distributed in future versions of Zoltan.
</li>
<li>
The OCTPART/OCTREE partitioning method is deprecated and will not be supported
in future versions of Zoltan. This method is now disabled by default in the
CMake build system; it can be enabled with CMake configuration flag
-DZoltan_ENABLE_OCT:BOOL=ON. Users should switch to Zoltan method HSFC
(Hilbert Space-Filling Curve partitioning), which should provide very similar
decompositions, or consider RCB partitioning.
</li>
</ul>
<!---------------------------------------------------------------------------->
<h2><a name="Backward v3.2"></a>
<hr>Backward Compatibility: Versions 3.2 and higher
</h2>
Interfaces to
<a href="ug_interface_color.html">Zoltan_Color</a>,
<a href="ug_interface_order.html">Zoltan_Order</a> and
<a href="ug_interface_lb.html#Zoltan_LB_Eval">Zoltan_LB_Eval</a> have changed.
<p>
The Zoltan native build environment, while still distributed, will no
longer be supported. Users should use the
<a href="ug_usage.html#Building the Library">autotools or CMake</a> systems.
Builds of the Zoltan F90 interface are supported in both autotools and
CMake.
<!---------------------------------------------------------------------------->
<h2><a name="Backward v3.1"></a>
<hr>Backward Compatibility: Versions 3.1 and higher
</h2>
Terminology referring to partitions and parts was clarified.
A "partition" describes the entire layout of the data across
processes. A "part" is a subset of the data assigned to a
single process. A partition is made up of many parts; the set
of all the parts is a partition.
<p>
We applied this naming convention more consistently throughout Zoltan.
Old parameters NUM_GLOBAL_PARTITIONS and NUM_LOCAL_PARTITIONS have been
more accurately renamed <a href="ug_alg.html#NUM_GLOBAL_PARTS">NUM_GLOBAL_PARTS</a> and
<a href="ug_alg.html#NUM_LOCAL_PARTS">NUM_LOCAL_PARTS</a>. Old query functions
ZOLTAN_PARTITIONS_MULTI_FN and ZOLTAN_PARTITION_FN have been more
accurately renamed
<a href="ug_query_lb.html#ZOLTAN_PART_MULTI_FN">ZOLTAN_PART_MULTI_FN</a>
and
<a href="ug_query_lb.html#ZOLTAN_PART_FN">ZOLTAN_PART_FN</a>.
However, in both cases, the old naming convention still works in the
Zoltan library.
<!---------------------------------------------------------------------------->
<h2><a name="Backward v3.0"></a>
<hr>Backward Compatibility: Versions 3.0 and higher
</h2>
A new naming convention was implemented to better categorize partitioning
methods. For more details, see parameters
<blockquote>
<a href="ug_alg.html#LB_METHOD">LB_METHOD</a>, <br>
<a href="ug_alg.html#LB_APPROACH">LB_APPROACH</a>, <br>
<a href="ug_alg_graph.html">GRAPH_PACKAGE</a>, and <br>
<a href="ug_alg_hypergraph.html">HYPERGRAPH_PACKAGE</a>.
</blockquote>
Former valid values of LB_METHOD should continue to work. In particular,
values of LB_METHOD for geometric partitioners
<a href="ug_alg_rcb.html">RCB</a>,
<a href="ug_alg_rib.html">RIB</a>,
<a href="ug_alg_hsfc.html">HSFC</a>, and
<a href="ug_alg_reftree.html">REFTREE</a> are unchanged.
<p>
The default graph partitioner has been changed from
<a href="ug_alg_parmetis.html">ParMETIS</a> to
<a href="ug_alg_phg.html">Zoltan PHG</a>. This change was made to
provide graph partitioning capability without reliance on the third-party
library ParMETIS.
<p>
Because Zoltan is designed primarily for dynamic load balancing,
The default partitioning approach
<a href="ug_alg.html#LB_APPROACH">LB_APPROACH</a>
is now "repartition." This change affects only Zoltan's hypergraph
partitioner <a href="ug_alg_phg.html">PHG</a>.
<!---------------------------------------------------------------------------->
<h2><a name="Backward v1.5"></a>
<hr>Backward Compatibility: Versions 1.5 and higher
</h2>
The ability to generate more parts than processors was added to Zoltan
in version 1.5. Thus, Zoltan's partitioning and migration routines were
enhanced to return and use both part assignments and processor assignments.
New interface and query functions were added to support this additional
information. All former Zoltan <a href="ug_param.html">parameters</a>
apply to the new functions as they did to the old; new parameters
<a href="ug_alg.html#NUM_GLOBAL_PARTS"><i>NUM_GLOBAL_PARTS</i></a>
and
<a href="ug_alg.html#NUM_LOCAL_PARTS"><i>NUM_LOCAL_PARTS</i></a>
apply only to the new functions.
<p>
The table below lists the Zoltan function that uses both part and
processor information, along with the analogous function that returns only
processor information. Applications requiring only one part per
processor can use either version of the functions.
<p>
<table border="1" cellpadding="5">
<tr>
<td>
<b>Function with Part and Processor info (v1.5 and higher)</b>
</td>
<td>
<b>Function with only Processor info (v1.3 and higher)</b>
</td>
</tr>
<tr>
<td>
<a href="ug_interface_lb.html#Zoltan_LB_Partition">Zoltan_LB_Partition</a>
</td>
<td>
<a href="ug_interface_lb.html#Zoltan_LB_Balance">Zoltan_LB_Balance</a>
</td>
</tr>
<tr>
<td>
<a href="ug_interface_augment.html#Zoltan_LB_Point_PP_Assign">Zoltan_LB_Point_PP_Assign</a>
</td>
<td>
<a href="ug_interface_augment.html#Zoltan_LB_Point_Assign">Zoltan_LB_Point_Assign</a>
</td>
</tr>
<tr>
<td>
<a href="ug_interface_augment.html#Zoltan_LB_Box_PP_Assign">Zoltan_LB_Box_PP_Assign</a>
</td>
<td>
<a href="ug_interface_augment.html#Zoltan_LB_Box_Assign">Zoltan_LB_Box_Assign</a>
</td>
</tr>
<tr>
<td>
<a href="ug_interface_mig.html#Zoltan_Invert_Lists">Zoltan_Invert_Lists</a>
</td>
<td>
<a href="ug_interface_mig.html#Zoltan_Compute_Destinations">Zoltan_Compute_Destinations</a>
</td>
</tr>
<tr>
<td>
<a href="ug_interface_mig.html#Zoltan_Migrate">Zoltan_Migrate</a>
</td>
<td>
<a href="ug_interface_mig.html#Zoltan_Help_Migrate">Zoltan_Help_Migrate</a>
</td>
</tr>
<tr>
<td>
<a href="ug_query_mig.html#ZOLTAN_PRE_MIGRATE_PP_FN">ZOLTAN_PRE_MIGRATE_PP_FN</a>
</td>
<td>
<a href="ug_query_mig.html#ZOLTAN_PRE_MIGRATE_FN">ZOLTAN_PRE_MIGRATE_FN</a>
</td>
</tr>
<tr>
<td>
<a href="ug_query_mig.html#ZOLTAN_MID_MIGRATE_PP_FN">ZOLTAN_MID_MIGRATE_PP_FN</a>
</td>
<td>
<a href="ug_query_mig.html#ZOLTAN_MID_MIGRATE_FN">ZOLTAN_MID_MIGRATE_FN</a>
</td>
</tr>
<tr>
<td>
<a href="ug_query_mig.html#ZOLTAN_POST_MIGRATE_PP_FN">ZOLTAN_POST_MIGRATE_PP_FN</a>
</td>
<td>
<a href="ug_query_mig.html#ZOLTAN_POST_MIGRATE_FN">ZOLTAN_POST_MIGRATE_FN</a>
</td>
</tr>
</table>
<p>
To continue using the v1.3 partition functions, no changes to C or Fortran90
applications are needed. Zoltan interfaces from versions earlier than 1.3
are also still supported (see
<a href="#Backward v1.3">below</a>),
requiring no changes to application programs.
<p>
To use the new v1.5 partitioning functions:
<ul>
<li>
C users must include file <i>zoltan.h</i> in their applications and edit
their applications to use the appropriate new functions.
</li>
<li>
Fortran90 users must put
<a href="ug_fortran_api.html#fortran ug api query">user-defined data types</a>
in <i>zoltan_user_data.f90</i> and edit their applications to
use the appropriate new functions. The new partitioning functions do not
work with user-defined data types in <i>lb_user_const.f90</i>.
</li>
</ul>
<!---------------------------------------------------------------------------->
<h2><a name="Backward v1.3"></a>
<hr>Backward Compatibility: Versions 1.3 and higher
</h2>
<p>
Versions of Zoltan before version 1.3 used a different naming convention for
the Zoltan interface and query functions. All functions in Zoltan v.1.3 and
above
are prefixed with <b>Zoltan_</b>; earlier versions were prefixed with
<b>LB_</b>.
<p>
<b>Zoltan versions 1.3 and above maintain backward compatibility with the
earlier
Zoltan interface.</b> Thus, applications that used earlier versions of Zoltan
can continue using Zoltan <b>without changing their source code</b>.
<p>
Only two
changes are needed to build the application with Zoltan v.1.3 and higher:
<ul>
<li>
All Zoltan include files are now in directory <i>Zoltan/include</i>.
Thus, application include paths must point to this directory.
<br>(Previously, include files were in <i>Zoltan/lb</i>.)
<li>
Applications link with Zoltan now by specifying only <i>-lzoltan</i>.
<br>(Previously, applications had to link with <i>-lzoltan -lzoltan_comm
-lzoltan_mem</i>.)
</ul>
<p>
While it is not necessary for application developers to modify their
source code to use Zoltan v.1.3 and above, those who want to update their
source code
should do the following in their application source files:
<ul>
<li>
Replace Zoltan calls and constants (<b>LB_*</b>) with new names. The new
names can be found through the <a href="#Backward Index">index below</a>.
<li>
C programs: Include file <i>zoltan.h</i> instead of <i>lbi_const.h</i>.
<li>
F90 programs: Put <a href="ug_fortran_api.html#fortran ug api query">user-defined data types</a> in file <i>zoltan_user_data.f90</i> instead of <i>lb_user_const.f90</i>.
</ul>
<!---------------------------------------------------------------------------->
<h4>
<a NAME="Backward Index"></a>Backward Compatilibity Index for Interface and Query Functions
</h4>
<table border="1" cellpadding="5">
<tr>
<td>
<b>Name in Earlier Zoltan Versions</b>
</td>
<td>
<b>Name in Zoltan Version 1.3 and higher</b>
</td>
</tr>
<tr>
<td>
LB_BORDER_OBJ_LIST_FN
</td>
<td>
<a href="ug_query_lb.html#ZOLTAN_BORDER_OBJ_LIST_FN">ZOLTAN_BORDER_OBJ_LIST_FN</a>
</td>
</tr>
<tr>
<td>
LB_Balance
</td>
<td>
<a href="ug_interface_lb.html#Zoltan_LB_Balance">Zoltan_LB_Balance</a>
</td>
</tr>
<tr>
<td>
LB_Box_Assign
</td>
<td>
<a href="ug_interface_augment.html#Zoltan_LB_Box_Assign">Zoltan_LB_Box_Assign</a>
</td>
</tr>
<tr>
<td>
LB_CHILD_LIST_FN
</td>
<td>
<a href="ug_query_lb.html#ZOLTAN_CHILD_LIST_FN">ZOLTAN_CHILD_LIST_FN</a>
</td>
</tr>
<tr>
<td>
LB_CHILD_WEIGHT_FN
</td>
<td>
<a href="ug_query_lb.html#ZOLTAN_CHILD_WEIGHT_FN">ZOLTAN_CHILD_WEIGHT_FN</a>
</td>
</tr>
<tr>
<td>
LB_COARSE_OBJ_LIST_FN
</td>
<td>
<a href="ug_query_lb.html#ZOLTAN_COARSE_OBJ_LIST_FN">ZOLTAN_COARSE_OBJ_LIST_FN</a>
</td>
</tr>
<tr>
<td>
LB_Compute_Destinations
</td>
<td>
<a href="ug_interface_mig.html#Zoltan_Compute_Destinations">Zoltan_Compute_Destinations</a>
</td>
</tr>
<tr>
<td>
LB_Create
</td>
<td>
<a href="ug_interface_init.html#Zoltan_Create">Zoltan_Create</a>
</td>
</tr>
<tr>
<td>
LB_Destroy
</td>
<td>
<a href="ug_interface_init.html#Zoltan_Destroy">Zoltan_Destroy</a>
</td>
</tr>
<tr>
<td>
LB_EDGE_LIST_FN
</td>
<td>
<a href="ug_query_lb.html#ZOLTAN_EDGE_LIST_FN">ZOLTAN_EDGE_LIST_FN</a>
</td>
</tr>
<tr>
<td>
LB_Eval
</td>
<td>
<a href="ug_interface_lb.html#Zoltan_LB_Eval">Zoltan_LB_Eval</a>
</td>
</tr>
<tr>
<td>
LB_FIRST_BORDER_OBJ_FN
</td>
<td>
<a href="ug_query_lb.html#ZOLTAN_FIRST_BORDER_OBJ_FN">ZOLTAN_FIRST_BORDER_OBJ_FN</a>
</td>
</tr>
<tr>
<td>
LB_FIRST_COARSE_OBJ_FN
</td>
<td>
<a href="ug_query_lb.html#ZOLTAN_FIRST_COARSE_OBJ_FN">ZOLTAN_FIRST_COARSE_OBJ_FN</a>
</td>
</tr>
<tr>
<td>
LB_FIRST_OBJ_FN
</td>
<td>
<a href="ug_query_lb.html#ZOLTAN_FIRST_OBJ_FN">ZOLTAN_FIRST_OBJ_FN</a>
</td>
</tr>
<tr>
<td>
LB_Free_Data
</td>
<td>
<a href="ug_interface_lb.html#Zoltan_LB_Free_Data">Zoltan_LB_Free_Data</a>
</td>
</tr>
<tr>
<td>
LB_GEOM_FN
</td>
<td>
<a href="ug_query_lb.html#ZOLTAN_GEOM_FN">ZOLTAN_GEOM_FN</a>
</td>
</tr>
<tr>
<td>
LB_Help_Migrate
</td>
<td>
<a href="ug_interface_mig.html#Zoltan_Help_Migrate">Zoltan_Help_Migrate</a>
</td>
</tr>
<tr>
<td>
LB_Initialize
</td>
<td>
<a href="ug_interface_init.html#Zoltan_Initialize">Zoltan_Initialize</a>
</td>
</tr>
<tr>
<td>
LB_MID_MIGRATE_FN
</td>
<td>
<a href="ug_query_mig.html#ZOLTAN_MID_MIGRATE_FN">ZOLTAN_MID_MIGRATE_FN</a>
</td>
</tr>
<tr>
<td>
LB_NEXT_BORDER_OBJ_FN
</td>
<td>
<a href="ug_query_lb.html#ZOLTAN_NEXT_BORDER_OBJ_FN">ZOLTAN_NEXT_BORDER_OBJ_FN</a>
</td>
</tr>
<tr>
<td>
LB_NEXT_COARSE_OBJ_FN
</td>
<td>
<a href="ug_query_lb.html#ZOLTAN_NEXT_COARSE_OBJ_FN">ZOLTAN_NEXT_COARSE_OBJ_FN</a>
</td>
</tr>
<tr>
<td>
LB_NEXT_OBJ_FN
</td>
<td>
<a href="ug_query_lb.html#ZOLTAN_NEXT_OBJ_FN">ZOLTAN_NEXT_OBJ_FN</a>
</td>
</tr>
<tr>
<td>
LB_NUM_BORDER_OBJ_FN
</td>
<td>
<a href="ug_query_lb.html#ZOLTAN_NUM_BORDER_OBJ_FN">ZOLTAN_NUM_BORDER_OBJ_FN</a>
</td>
</tr>
<tr>
<td>
LB_NUM_CHILD_FN
</td>
<td>
<a href="ug_query_lb.html#ZOLTAN_NUM_CHILD_FN">ZOLTAN_NUM_CHILD_FN</a>
</td>
</tr>
<tr>
<td>
LB_NUM_COARSE_OBJ_FN
</td>
<td>
<a href="ug_query_lb.html#ZOLTAN_NUM_COARSE_OBJ_FN">ZOLTAN_NUM_COARSE_OBJ_FN</a>
</td>
</tr>
<tr>
<td>
LB_NUM_EDGES_FN
</td>
<td>
<a href="ug_query_lb.html#ZOLTAN_NUM_EDGES_FN">ZOLTAN_NUM_EDGES_FN</a>
</td>
</tr>
<tr>
<td>
LB_NUM_GEOM_FN
</td>
<td>
<a href="ug_query_lb.html#ZOLTAN_NUM_GEOM_FN">ZOLTAN_NUM_GEOM_FN</a>
</td>
</tr>
<tr>
<td>
LB_NUM_OBJ_FN
</td>
<td>
<a href="ug_query_lb.html#ZOLTAN_NUM_OBJ_FN">ZOLTAN_NUM_OBJ_FN</a>
</td>
</tr>
<tr>
<td>
LB_OBJ_LIST_FN
</td>
<td>
<a href="ug_query_lb.html#ZOLTAN_OBJ_LIST_FN">ZOLTAN_OBJ_LIST_FN</a>
</td>
</tr>
<tr>
<td>
LB_OBJ_SIZE_FN
</td>
<td>
<a href="ug_query_mig.html#ZOLTAN_OBJ_SIZE_FN">ZOLTAN_OBJ_SIZE_FN</a>
</td>
</tr>
<tr>
<td>
LB_PACK_OBJ_FN
</td>
<td>
<a href="ug_query_mig.html#ZOLTAN_PACK_OBJ_FN">ZOLTAN_PACK_OBJ_FN</a>
</td>
</tr>
<tr>
<td>
LB_POST_MIGRATE_FN
</td>
<td>
<a href="ug_query_mig.html#ZOLTAN_POST_MIGRATE_FN">ZOLTAN_POST_MIGRATE_FN</a>
</td>
</tr>
<tr>
<td>
LB_PRE_MIGRATE_FN
</td>
<td>
<a href="ug_query_mig.html#ZOLTAN_PRE_MIGRATE_FN">ZOLTAN_PRE_MIGRATE_FN</a>
</td>
</tr>
<tr>
<td>
LB_Point_Assign
</td>
<td>
<a href="ug_interface_augment.html#Zoltan_LB_Point_Assign">Zoltan_LB_Point_Assign</a>
</td>
</tr>
<tr>
<td>
LB_Set_Fn
</td>
<td>
<a href="ug_interface_init.html#Zoltan_Set_Fn">Zoltan_Set_Fn</a>
</td>
</tr>
<tr>
<td>
LB_Set_&lt;<i>lb_fn_type</i>>_Fn
</td>
<td>
<a href="ug_interface_init.html#Zoltan_Set_Specific_Fn">Zoltan_Set_&lt;<i>zoltan_fn_type</i>>_Fn</a>
</td>
</tr>
<tr>
<td>
LB_Set_Method
</td>
<td>
<a href="ug_interface_init.html#Zoltan_Set_Param">Zoltan_Set_Param</a>
with parameter <a href="ug_alg.html#LB_METHOD"><i>LB_METHOD</i></a>
</td>
</tr>
<tr>
<td>
LB_Set_Param
</td>
<td>
<a href="ug_interface_init.html#Zoltan_Set_Param">Zoltan_Set_Param</a>
</td>
</tr>
<tr>
<td>
LB_UNPACK_OBJ_FN
</td>
<td>
<a href="ug_query_mig.html#ZOLTAN_UNPACK_OBJ_FN">ZOLTAN_UNPACK_OBJ_FN</a>
</td>
</tr>
</table>
<hr WIDTH="100%">[<a href="ug.html">Table of Contents</a>&nbsp; | <a href="ug_refs.html">Next:&nbsp; References</a>&nbsp; |&nbsp; <a href="ug_release.html">Previous:&nbsp; Release Notes</a>&nbsp; |&nbsp; <a href="https://www.sandia.gov/general/privacy-security/index.html">Privacy and Security</a>]
</body>
</html>