Cloned library of VTK-5.0.0 with extra build files for internal package management.
You can not select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
 
 
 
 
 
 

158 lines
5.3 KiB

/*
* Copyright (c) 1994 Sandia Corporation. Under the terms of Contract
* DE-AC04-94AL85000 with Sandia Corporation, the U.S. Governement
* retains certain rights in this software.
*
* Redistribution and use in source and binary forms, with or without
* modification, are permitted provided that the following conditions are
* met:
*
* * Redistributions of source code must retain the above copyright
* notice, this list of conditions and the following disclaimer.
*
* * Redistributions in binary form must reproduce the above
* copyright notice, this list of conditions and the following
* disclaimer in the documentation and/or other materials provided
* with the distribution.
*
* * Neither the name of Sandia Corporation nor the names of its
* contributors may be used to endorse or promote products derived
* from this software without specific prior written permission.
*
* THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS
* "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT
* LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR
* A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT
* OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
* SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT
* LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE,
* DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
* THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
* (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE
* OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
*
*/
/*****************************************************************************
*
* exgvan - ex_get_var_names
*
* author - Sandia National Laboratories
* Larry A. Schoof - Original
* James A. Schutt - 8 byte float and standard C definitions
* Vic Yarberry - Added headers and error logging
*
*
* environment - UNIX
*
* entry conditions -
* input parameters:
* int exoid exodus file id
* char* var_type variable type: G,N, or E
* int num_vars # of variables to read
*
* exit conditions -
* char* var_names ptr array of variable names
*
* revision history -
*
* $Id: exgvan.c,v 1.2 2005/07/19 22:11:53 andy Exp $
*
*****************************************************************************/
#include "exodusII.h"
#include "exodusII_int.h"
/*
* reads the names of the results variables from the database
*/
int ex_get_var_names (int exoid,
const char *var_type,
int num_vars,
char *var_names[])
{
int i, varid, status;
char errmsg[MAX_ERR_LENGTH];
exerrval = 0; /* clear error code */
/* inquire previously defined variables */
if (*var_type == 'g' || *var_type == 'G') {
if ((varid = ncvarid (exoid, VAR_NAME_GLO_VAR)) == -1) {
exerrval = ncerr;
sprintf(errmsg,
"Warning: no global variables names stored in file id %d", exoid);
ex_err("ex_get_var_names",errmsg,exerrval);
return (EX_WARN);
}
}
else if (*var_type == 'n' || *var_type == 'N') {
if ((varid = ncvarid (exoid, VAR_NAME_NOD_VAR)) == -1) {
exerrval = ncerr;
sprintf(errmsg,
"Warning: no nodal variable names stored in file id %d",
exoid);
ex_err("ex_get_var_names",errmsg,exerrval);
return (EX_WARN);
}
}
else if (*var_type == 'e' || *var_type == 'E') {
if ((varid = ncvarid (exoid, VAR_NAME_ELE_VAR)) == -1) {
exerrval = ncerr;
sprintf(errmsg,
"Warning: no element variable names stored in file id %d",
exoid);
ex_err("ex_get_var_names",errmsg,exerrval);
return (EX_WARN);
}
}
else /* invalid variable type */
{
exerrval = EX_BADPARAM;
sprintf(errmsg,
"Error: Invalid variable type %c specified in file id %d",
*var_type, exoid);
ex_err("ex_put_var_names",errmsg,exerrval);
return (EX_WARN);
}
/* read the variable names */
/*
* See if reading into contiguous memory in which case we can load
* all values in one call. If not, we must load each name individually.
*/
if ((size_t)(&var_names[num_vars-1][0] - &var_names[0][0]) ==
sizeof(char)*(MAX_STR_LENGTH+1)*(num_vars-1)) {
status = nc_get_var_text(exoid, varid, &var_names[0][0]);
if (status == -1) {
exerrval = ncerr;
sprintf(errmsg,
"Error: failed to get results variable names from file id %d", exoid);
ex_err("ex_get_var_names",errmsg,exerrval);
return (EX_FATAL);
}
} else {
for (i=0; i<num_vars; i++) {
size_t start[2];
size_t count[2];
start[0] = i; count[0] = 1;
start[1] = 0; count[1] = MAX_STR_LENGTH+1;
status = nc_get_vara_text(exoid, varid, start, count, var_names[i]);
if (status == -1) {
exerrval = ncerr;
sprintf(errmsg,
"Error: failed to get results variable names from file id %d", exoid);
ex_err("ex_get_var_names",errmsg,exerrval);
return (EX_FATAL);
}
}
}
return (EX_NOERR);
}